06233 872 300 info@cmc.de

The following standards apply to films:

Size Norm
Tensile strength DIN 53455
Elongation at break DIN 53455
Tear Resistance DIN 53363, ASTM D1922E
Modulus of elasticity DIN 53457
Elasticity DIN 53445
Impact resistance DIN 53453
Flexural Strength DIN 53262
Coefficient of friction DIN 53375
Cold Resistance DIN 53375
Shine DIN 67530, ASTM D2457
Transparency, Turbidity DIN 5036, ASTM D1003-61
Refractive Index DIN 53491
Specific Volume Resistivity DIN 40634
Oberflächenwiderstand  DIN 53482
Durchschlagsfestigkeit DIN 40634
Dielektrizitätszahl DIN 40634
Dielektrischer Verlustfaktor DIN 40634
Wasserdampfdurchlässigkeit DIN 53122
Gasdurchlässigkeit DIN 53122, DIN 53380

Additional overview of important standards related to electrical insulation:

  • IEC 60085 Electrical Insulation, Thermal Rating, and Marking

  • IEC 60112 Methods for determining the test number and comparison number for creep path formation in solid insulating materials

  • IEC 60172 Test method for determining the temperature index of enameled wires

  • IEC 60216 Electrical insulating materials – Properties relating to long-term thermal behavior

  • IEC 60243 Electrical breakdown strength of insulating materials—Test methods

  • IEC 60343 Recommended test methods for determining the relative resistance of insulating materials to breakdown due to surface partial discharge

  • IEC 60454 Specifications for self-adhesive insulating tapes for electrotechnical applications

  • IEC 60505 Evaluation and marking of electrical insulation systems

  • IEC 60674 Specification for plastic insulating films for electrotechnical purposes

  • IEC 61234 Test methods for the hydrolytic resistance of electrical insulating materials

  • IEC 61857 Electrical insulating systems – Methods for thermal evaluation

  • IEC 61858 Electrical Insulation Systems – Thermal Evaluation of Changes in a Tested Electrical Insulation System (EIS)

  • IEC/TS 61934 Electrical measurement of partial discharges (PD) under repetitive voltage pulses with short rise times

  • IEC 62068 Electrical insulating materials and insulating systems – General method for evaluating electrical life under repetitive voltage pulse stress

  • EN 61558 Safety of transformers, power supplies, chokes, and similar equipment

  • UL 746B Polymer materials – Evaluation of long-term properties

  • UL 1446 Insulation material systems – General

  • ASTM D 2275 Test for dielectric strength of solid insulating materials under the influence of surface partial discharges

In addition to the basic standard DIN IEC 60664 (Insulation Coordination), there is a draft application guide (design examples and insulation tests) for Part 2 (DIN IEC 60664-2-1).

When determining the PTI (Proof Tracking Index) and the CTI (Comparative Tracking Index), the IEC 60112 standard proceeds as follows:
In the first step, a conductive liquid is dripped between two platinum electrodes resting flat on the surface of the insulating material (up to 50 drops every 30 seconds). This simulates condensation and surface contamination.

The voltage is gradually increased until either the current exceeds 0.5 A or ignition and erosion occur. The highest voltage at which the test specimen does not fail is verified at five points. This voltage is the PTI value (the test rating).

In the second step, the determined voltage is reduced by the PTI value and 25 V. Using this voltage, the material is tested at five different locations with 50 or 100 drops every 30 seconds. If the test specimen passes the test, this voltage then becomes the determined comparative number (CTI value).

It is important to note that higher frequencies are not covered by the standard, yet they have a significant influence on the formation of a creep path. Electrochemical migration is also not taken into account due to the relatively short test duration (50 × 30 seconds = 25 minutes).

In many cases, the CTI value in “volts” and the unitless PTI test number are used interchangeably (e.g., CTI = 1 actually corresponds to CTI = 400…599 V or Insulation Material Group II).

The international “adhesive tape standard” IEC 60454

The IEC 60454 series of standards describes common technical adhesive tapes intended for use in electrical engineering (self-adhesive tapes for electrical engineering applications).
Part 1 of the standard describes the general requirements for the various adhesive tapes.
Part 2 outlines the corresponding test methods. In addition to minimum mechanical properties, typical specifications include breakdown voltage (voltage resistance), electrolytic corrosion resistance, and long-term thermal behavior.
Part 3 specifies the typical values for the insulating material (adhesive tape backing) and the adhesive in various material data sheets.

Fire resistance classes according to DIN 4102 (e.g., B1)

In the construction industry, materials are classified according to their flammability in accordance with DIN 4102, among other standards.

Building materials are categorized based on the classification specified in DIN 4102-4. If a building material is not listed there, it requires a corresponding certificate of suitability for use in accordance with the State Building Code. For other industrial sectors, classification based on flammability properties is normally sufficient without the need for an additional certificate of suitability for use.

The flammability classes are categorized as follows:
• Fire resistance class A includes materials that are non-combustible. These include concrete, sand, gravel, building ceramics, steel, cast iron, and foam glass.
• Fire resistance class A1: Non-combustible materials that contain no organic components, such as mineral fiber components or glass wool.
• Fire resistance class A2: These are non-combustible materials combined with organic, combustible components. Examples include polystyrene concrete, gypsum board, or mineral wool.
• Fire resistance class B includes materials that are combustible.
• Fire resistance class B1: This class encompasses materials that are flame-retardant. These can include rigid foam plastics, fire-retardant wood-based materials, or appropriately classified adhesive tapes. The fire must extinguish itself once the ignition source is removed. In addition, the test – known as the “fire shaft test” – measures, among other things, the smoke gas temperature (below 200°C) and the remaining length of the unburned test material.
• Fire protection class B2: This includes normally flammable materials, such as wooden components thicker than 2 mm.
• Fire protection class B3: This includes highly flammable materials. These are not considered in standard fire protection assessments, as they have the opposite effect of the desired protective measure.