06233 872 300 info@cmc.de

Copper Shielding Tape

for EMC shielding, high-current cables, and transformers

COPPER

Our Shielding Tapes

Copper shielding strips are flat, insulated copper conductors used in transformers, coils, busbars, and EMC applications. They offer high current-carrying capacity, low reactance, and enable compact windings with excellent heat dissipation.

BENEFITS

Copper Shielding Tapes

Copper Shielding Tape

Insulated copper strips for EMC shielding, high-current cables, and transformers

Reduced skin effect below 100 kHz

High current-carrying capacity

Very dense windings are possible

Low inductive reactance

Prevents short circuits

Copper shielding tapes offer high current-carrying capacity due to their large conductor surface area and enable particularly dense windings, which significantly reduce vibrations such as the typical 50-Hz hum. Thanks to their low inductive reactance in the range from 5 Hz to 50 kHz and the reduced skin effect below 100 kHz, they operate extremely efficiently in transformers, coils, and EMC applications. At the same time, they offer an optimal ratio of heat dissipation to power, low capacitive components, and the ability to reliably prevent short circuits between turns- ideal for audio applications, busbars, or induction loops.


The strips are manufactured from soft electrolytic copper E-Cu 58 with a resistivity of 0.017 Ω·mm²/m. The available copper foils range in thickness from 35 µm to 300 µm, with an optional ultra-thin version as thin as 10 µm. This allows for conductor cross-sections ranging from approximately 0.1 mm² to 45 mm². Depending on the version, roll widths ranging from 5 mm to 300 mm are available. The current-carrying capacity typically ranges from 2 A to 2.5 A per mm² under moderate heating. In addition to standard copper foils, bare blanks and aluminum alternatives are also available, allowing the strips to be flexibly adapted to various thermal, mechanical, and electrical requirements.

Materials & Technical Specifications

  • Copper foil thicknesses: 35–300 µm (other thicknesses available upon request)
  • Conductor cross-sections: approx. 0.1–45 mm²
  • Material: electrolytic copper E-Cu 58, soft
  • Specific resistance: 0.017 Ω·mm²/m
  • Current-carrying capacity: approx. 2–2.5 A per mm² (with moderate heating)

     

    Options:
    • 10 µm copper foil (super-flat)
    • bare copper foil, cut to size
    • alternatively, aluminum foil

    Form of delivery:
    Roll width: 5–300 mm (depending on thickness and version)

Insulation Types (Single-layer & Double-layer)

Single-layer insulation
• Polyester, Nomex, Kapton, PEN
• Series: CMC 38181–38481, 38191–38491, 38182–38482, 38190–38490, 38192–38492
• UL-listed (colorless polyester)

2-layer insulation
• Polyester, Kapton, PEN
• Series: CMC 38193, 38393, 38493, 38194, 38394, 38494

Additional Design Options

Parallel, individually insulated power cables
• Ideal for LED furniture lighting
• Self-adhesive → easy installation
• Extremely low profile

Shield windings (EMC shield)

Copper foils act as Faraday cages between windings and drastically reduce capacitive coupling. Applications include:
◦ Ring transformers
◦ Additional insulation protection
◦ Fault current interception via shielding windings
◦ Combinations of copper and aluminum laminates

Advantages of Insulated Copper Tapes
• Prevent capacitive coupling
• Increase safety between primary and secondary circuits
• Large surface area → substitute for stranded wire
• Suitable for use up to Class H
• High-current capable (e.g., TIG welding)
• Complies with clearances and creepage distances
• Solder gap for easy wire connection
• Insulated on one or both sides
• Available in many widths and thicknesses

Proper Handling

It is particularly important to protect the delicate edges. Thin insulation (e.g., CMC 38190) can be damaged if stored improperly → resulting in a decrease in dielectric strength. Installation instructions are available as a document.

High-Current Applications

  • • Copper foils up to 1,000 µm
    • Flat copper conductors up to 1,500 µm
    • Used in solar inverters and chargers for electric vehicles
    • Note: Dielectric strength depends on temperature and frequency
    • Pulsed edges (in the nanosecond range) stress the insulation → Avoid partial discharges
    • Custom solutions available

Multiple Cables

For DC power supplies (e.g., LEDs):
• Combination of copper conductor + tinned copper conductor → reverse polarity protection
• Up to 3 insulated flat copper wires can be run side by side

Current-Carrying Capacity (Single Conductor)

Ambient temperature 30°C (self-heating approx. 30°C)

  • 0,75 mm² → 6 A
  • 1,00 mm² → 10 A
  • 1,5 mm² → 13 A

40 °C:

  • 0,75 mm² → 4,9 A
  • 1,00 mm² → 8,2 A
  • 1,5 mm² → 10,7 A

50 °C:

  • 0,75 mm² → 3,5 A
  • 1,00 mm² → 5,8 A
  • 1,5 mm² → 7,5 A

Example: CMC 91100 → 30 µm copper foil, 25 mm wide → 0.75 mm²

Custom Solutions & Custom-Made Products

If no standard product meets your needs, we’ll work with you to develop a custom solution:

• Custom adhesive tapes
• Die-cut parts based on drawings
• Special material combinations
• Custom widths and shapes

    Request a Custom Solution Now

    BENEFITS

    Why Choose CMC Adhesive Technology?

    CMC Klebetechnik stands for diversity, precision, and true development expertise. With over 200 product types, the company offers solutions for virtually any technical application. Thanks to in-house development, it creates custom adhesive tapes and functional films that are precisely tailored to specific requirements. Precise manufacturing enables roll widths ranging from 0.8 mm to 1,000 mm - perfect for mass production, custom formats, and demanding industries.
    With decades of experience in electrical engineering, the automotive industry, mechanical engineering, energy, and many other sectors, CMC Klebetechnik delivers reliable results of the highest standard. And it’s all Made in Germany - for quality, technical precision, and maximum reliability.

    Over 60 years of experience

    Cross-Industry Expertise

    In-house coating facilities

    Rapid Sample & Prototype Production

    Sustainable, Responsible Production

    Made in Germany

    FAQ

    Questions & Answers

    What are copper shielding tapes used for?

    Copper shielding tape serves as a flat, insulated copper conductor for transformers, coils, EMC shielding, busbars, and high-current applications. It reduces capacitive coupling, improves safety between primary and secondary windings, and enables compact, low-vibration windings.

    What are the advantages of copper foil over round wire or stranded wire?

    Copper foil has a large surface area, which reduces the skin effect and allows high frequencies to be transmitted more efficiently. Windings become denser, mechanically more stable, and thermally more conductive. In addition, inductive reactance and capacitive components are reduced.

    What material thicknesses and widths are available?

    Copper foils are typically available in thicknesses ranging from 35 to 300 µm, with 10 µm also available as an option. Roll widths range from approximately 5 mm to 300 mm, depending on the type.

    What is the current-carrying capacity?

    The current-carrying capacity is approximately 2–2.5 A per mm² under moderate heating conditions. For high-current applications, thicker foils up to 1,000 µm and flat copper conductors up to 1,500 µm are also available.

    What types of insulation are available?

    Depending on the series, polyester, Nomex, Kapton, or PEN are available – with single or double insulation. Some versions are UL-recognized. Multi-layer insulation (e.g., Class F or H) is also available.

    Can copper foil be used as EMC shielding?

    Yes. Copper foils act as a Faraday cage and reduce capacitive coupling between windings. They increase safety, prevent short circuits between turns, and can absorb fault currents.

    Are there self-adhesive versions?

    Yes, self-adhesive, insulated flat copper cables are available – ideal for LED applications or flat power distribution in furniture.

    Which applications are particularly suitable?
    • Transformers (Toroidal & Power)

    • EMC shielding windings

    • High-current cables (e.g., welding machines, solar inverters)

    • Audio technology

    • Induction loops / hearing assistance systems

    • Busbars and compact DC power supplies

    What should be kept in mind during processing?

    The edges of the film must be protected, as thin insulation is delicate. Damage can reduce the film’s dielectric strength. Installation instructions are available as a document.

    Are there custom solutions?

    Yes. Widths, thicknesses, insulation, multi-conductor cables, and combinations of copper and aluminum laminates can be custom-manufactured.

    We're happy to help!

    Gabriele Sältzer

    Customer Service

     

    Phone: +49 6233 872 351

    Email: saeltzer@cmc.de