The internal “wiring” of electronic devices is often handled using so-called FPCs (flexible printed circuits). These cables – some of which are highly complex – function as flexible “circuit boards” to connect components to one another. Side connections and branches can be implemented relatively easily. In other cases, the main consideration is installation space, as the flat cables can be routed almost anywhere. However, longer cable runs can lead to high susceptibility to electromagnetic interference.
For many years, laminated, very flat cables (FLC, flat laminated cable) have been used when longer distances need to be bridged. Their advantage is their relatively simple manufacturing process, as parallel copper conductors are laminated between two insulating films. This is significantly less labor-intensive compared to printed, flexible conductors.
To prevent these cables from acting as transmitting antennas and to make them resistant to externally induced interference, they are shielded. CMC Klebetechnik manufactures a thin shielding film (CMC 39504) that was specifically developed for the production of shielded flat cables.
A 9 µm-thick aluminum layer serves as the EMC/EMI shield. It is electrically insulated by a 12 µm polyester film.
The adhesive applied to the aluminum side can be heat-activated at approximately 120°C. This allows the EMC shield to be laminated in the same manner and on the same equipment as the cable itself. In addition, the adhesive is formulated to be electrically conductive (in the Z-direction only). If the insulation of the laminated cable is opened at appropriate intervals to expose one of the laminated conductors, the shield can be continuously grounded via the electrically conductive adhesive.
Due to the CMC 39504’s minimal thickness of only 55 µm, the effective EMC shield adds virtually no bulk to the FLC (flexible laminated cable). The heat-activated adhesive ensures excellent adhesion and resistance to repeated bending, while its electrical conductivity ensures effective grounding of the shield. It therefore counteracts not only electromagnetically induced eddy currents but also equalizing currents flowing through the shield.
The outer polyester film of CMC 39504 achieves a breakdown voltage of > 3,000 Veff. Thus, even at the standard test voltages for such laminated cables, no breakdown is to be expected, and electrical safety is ensured over the long term. The polyester film is comparatively robust mechanically and also protects against occasional chafing and rubbing.
CMC 39504 is the ideal solution for shielding laminated cables; it adds virtually no bulk and can be applied directly during cable manufacturing.