06233 872 300 info@cmc.de

>> Here is a link to the UL website where you can enter the e-file number directly: UL Prospector

File-Number der CMC Produkte bei UL: OANZ2, E93622

(This page contains a comprehensive Underwriter Laboratories database of UL-recognized insulating materials. Link to the original excerpt from the UL database for CMC Klebetechnik products: E93622)

UL file numbers for the films:

Manufacturer Trade name Ul-File
Du Pont Mylar® A E93687
Mitsubishi Hostaphan® RN E53895
Covestro Makrofol® EN E168120
Toyobo Teonex® E51743
Sabic Ultem® E103380
Saint Gobain Norton FEP E311412
Du Pont Nomex® 410, 411, E 56A E34739
Du Pont Kapton® E39505
Victrex Aptiv™ E161131
Toray Torelina® E86423

    Insulation Systems for Manufacturers of Transformers and Electric Motors

    Insulation systems offer significant cost-saving potential for component manufacturers when supplying customers or exporting to countries that require UL certification. By using only UL-listed components (coil forms, impregnating resin, enameled wire, insulating tape), for example, in a transformer, the certification process can be significantly simplified and, above all, shortened.
    Insulation systems combine proven insulation materials that have been tested, for example, via the Sealed Tube Test.

    Several electrical insulation tapes from CMC Klebetechnik are approved for use in the following insulation systems (Class B/F) from DuPont:

    • Class 130 Crastin® PBT, Mylar®, Nomex®, Herberts® Electro C190HE
    • Class 155 Crastin® PBT, Mylar®, Nomex®, Herberts® Electro C290HE
    • Class 130 Rynite® PET, Mylar®, Nomex®, Herberts® Electro R150HE
    • Class 155 Rynite® PET, Mylar®, Nomex®, Herberts® Electro R201HE
    • Class 155 Rynite® PET, Mylar®, Nomex®, Herberts® Electro R203HE
    • Class 155 Zytel®, Crastin® PBT, Mylar®, Nomex®, Herberts® Electro CZ255HE
    • Class 130 Zytel®, Mylar®, Nomex®, Herberts® Electro Z130HE
    • Class 130 Zytel®, Mylar®, Nomex®, Herberts® Electro Z150HE
    • Class 155 Zytel®, Mylar®, Nomex®, Herberts® Electro Z200HE

      Another interesting website for researching insulation materials can be found at http://www.ul.com/database

      This site contains a comprehensive database from Underwriter Laboratories of UL-listed insulation materials.

      The tapes listed in the EIS include the following types:

      CMC 10966, 10820, 65120, 65100, 70100, 70110, 80725, 16100, 84170, 84160, 84150, 65768, 16701, 18102, 16700, 17713, 65767 (materials used: polyester, Nomex, polyester nonwoven, Kapton, crepe paper, glass fabric).

      There are many other insulation systems using adhesive tapes from CMC Klebetechnik; however, these were submitted to UL by individual customers and are not available for general use.

        Comparison of UL 510, UL 746, and UL 94 Standards Regarding Flammability

        UL distinguishes between (homogeneous) plastics, whose property requirements are described in the UL 746 series of standards, and UL 510, which is a specific standard for electrical insulating adhesive tapes.
        The tests and test methods differ, in some cases significantly.
        The UL 94 test standard is used to test the flammability of plastics that are structural components of devices and enclosures. It is NOT intended for adhesive tapes. Sample thickness is typically 0.4 mm to 3 mm. The samples are exposed to flame vertically and horizontally.
        For thin films, the test is modified, and the results are reported as follows: UL 94 – VTM0 (TM stands for Thin Material).
        In the UL 510 test, however, the adhesive tape is wound three times around a metal rod with a 50% overlap and then exposed to a flame. In this test, even polyester adhesive tapes (PET: UL 94 – VTM2) achieve the “flame-retardant” rating.
        The UL 510 test method is therefore in no way comparable to the flame test in UL 94. That is why adhesive tapes with a UL 94 rating are not commonly available!

        UL510 und IEC 60454

        Beide Normen UL 510 und IEC 60454 sind für Klebebänder zutreffend (auch ehemals DIN 40633, VDE 0340).

        Prinzip des Tests bezüglich Brennbarkeit:

        Drei Lagen Klebeband werden überlappend auf einen Stahlstab gewickelt. Dann wird eine definierte Flamme fünfmal für 15s mit 15s Pause dazwischen an den Prüfling herangeführt. Bestanden wenn (Kurzfassung): Kein Weiterbrennen über 60s hinaus und kein Abtropfen von brennendem oder glimmendem Material bei keiner der fünf Beflammungen.

        Testergebnis wenn bestanden: flammwidrig

        UL Standard UL-94-VTM – Applies to plastics in sheet or film form

        A test specimen (12.7 mm) is suspended vertically in the test area and exposed to a Bunsen burner flame. For thin materials (films, thin materials = TM), the test specimen is clamped into a frame designed to prevent the specimen from curling up when exposed to the flame. This test is normally intended for materials 2 mm or thicker and is not intended for adhesive tapes.
        One group of films that are only slightly flammable and have very good self-extinguishing properties is the CMC 27xxx product group (polypropylene films with UL 94 V-0 classification). Furthermore, Nomex and Kapton adhesive tapes have similarly good properties.

        Result:

        • V-0: The flame extinguishes within 10 seconds
        • V-1: The flame extinguishes within 30 seconds, and no burning material drips down
        • V-2: The flame extinguishes within 30 seconds, but dripping may occur
        • DIN 40633: Flammability Classes
        • Bu1 – Bu3: Bu1 and Bu2 as described above
        • Bu3: burns for longer than 30 seconds but extinguishes within 60 seconds

        Corresponds to the UL 94 V test; however, the test specimen is placed horizontally in the test flame. This test is less stringent with regard to the material’s self-extinguishing properties.

        Typical requirements for electrical products used in outdoor applications according to UL 746C (e.g., solar inverters): 

        UL 94 VTM0, 5 kV breakdown voltage, CTI=2, HAI=3, HWI=4
        UL 94 VTM2, 5 kV breakdown voltage, CTI=2, HAI=2, HWI=2

         

        UL 746C
        Target Kapton FN *
        Kapton XP919*
        Formex GK
        Kapton HN
        Kapton MT
        Aptiv 1000*
        Nomex 410
        Mylar A
        CTI ** 2 (>3) 1 1 0 4 4 3 3 1
        HAI 3 (>4) 4 0 0 4 1 4 3 4
        HWI 4 (>5) 0 0 4 0 0 5 0 5
        UL 94 0 (>1) 0 0 0 0 0 1 0 2
        Heat class H, 240°C H, 240°C 115°C H, 240°C H, 240°C H H B
        Usability No Yes Yes No No No No No

         

        * Not a standard product; not in stock
        ** Depends on the contamination class; for classes 1 or 2, CTI=4 is sufficient; for contamination class 3, CTI=3 is required
        For further details, particularly regarding film properties, please refer to the “Link to UL” (enter the file number in the search window on the UL website) or consult our list of links (under “General Information”) to access the manufacturers’ websites directly. The adhesives used are typically rated for a continuous operating temperature of at least 130°C. Many of our UL-recognized adhesive tapes have been tested in accordance with UL 510 and are often flame-retardant. For many films (e.g., Kapton), there are variants designed for specific requirements such as corona resistance, thermal conductivity, or creep current resistance. Nearly all adhesives are characterized by very good resistance to impregnating agents. However, due to the wide variety of impregnating agents, it is not possible to make a general statement. Further information on the processing of adhesive tapes and the adhesives used.

        Note on “flameability”: UL 94 is the standard for insulation materials. The suffix “H” refers to a “horizontal” orientation, and “V” refers to a “vertical” orientation of the test specimen during the burn test. “VTM” indicates that a thin insulation material (typically a film) was tested in a vertical orientation. The standard for adhesive tapes is UL 510. The test setup differs in that the adhesive tape is applied to “something” (a steel rod), as it would be in its intended use, and is then exposed to a flame (similar to IEC 60454-2).

        Basic Information About the UL 1446 Standard

        Electrical products are expected to meet a well-established technical standard and to offer a high level of reliability and operational safety. Compliance with these safety requirements is demonstrated through certification.

        UL 1446, Issue 7 – All New?