Why It Happens – and How to Prevent It
Electrochemical migration (ECM) is an often-underestimated risk in electrical assemblies. While it used to occur primarily on printed circuit boards with very closely spaced traces, the issue is now becoming significantly more important due to higher operating voltages – for example, in electric mobility. Systems operating at 350–900 VDC are particularly at risk because the conditions for ECM are significantly more severe in these cases.
This article explains in simple terms how electrochemical migration occurs, what factors contribute to it, and how developers can effectively reduce the risk.
What is electrochemical migration?
Electrochemical migration refers to the formation of conductive metal dendrites that grow between two conductors and can thereby bridge an insulation gap. These dendrites form when metal ions migrate through an electric field and redeposit elsewhere.
The consequences can be severe:
• Reduction in the insulation distance
• Formation of creep paths
• Short circuits
• Sporadic field failures that are barely detectable in production
Particularly critical: ECM occurs primarily in direct current (DC) applications, as the constant electric field promotes ion migration.
Why Does ECM Occur? The Most Important Contributing Factors
ECM requires one thing above all else: moisture. This doesn’t even have to be in the form of condensation—high humidity is sufficient, since many materials can absorb water (e.g., polyamide).
Other contributing factors:
• Large potential differences
• Conductivity of the substrate
• Contamination and environmental influences
• Vulnerable insulation materials
• Conductor materials prone to whisker formation
Industries such as solar technology and wind power have been familiar with this problem for years, as their systems are exposed to significant climatic fluctuations.
How can this risk be minimized?
The new Annex A of IEC 60664-1 (informative) recommends several measures to prevent or significantly reduce ECM:
1. Protective Varnishes and Coatings
Coatings on printed circuit boards prevent moisture from coming into direct contact with the conductive traces.
2. Suitable Metal Materials
Metals with higher resistance to electrochemical migration reduce ion migration.
3. High-quality insulation materials
Insulators with high insulation resistance are crucial. Important: At resistances below 10⁸ ohms, ECM can occur even in the absence of moisture.
4. Well-designed housing construction
- Prevent Condensation
- High IP ratings
- Proper placement of the assembly
If condensation cannot be avoided:
• Anti-condensation heaters
• Self-heating through electrical resistance
5. Greater distances
As with creep zones, the rule is: distance equals safety.
6. Prevent Contamination
Residues on printed circuit boards, encapsulants, or surfaces can significantly promote ECM.
ECM as a Hidden Cause of Errors
The tricky thing about electrochemical migration is that it’s barely noticeable during production. It’s only in the field – often sporadically – that failures occur, indicating a weakness in design or material selection.
That’s precisely why it’s important to take ECM into account as early as the development phase.
Insulation Products from CMC
CMC Klebetechnik offers a wide selection of materials that can counteract ECM:
• Films with a high CTI rating (up to >600 V)
• High-temperature-resistant films (up to >300°C)
• Materials with low water absorption
Developers can describe their application and operating conditions—CMC will assist in selecting the optimal product.